CHALLENGES AND POSSIBLE SOLUTIONS IN DETERMINING INR
Atherothrombosis Journal
View Archive InfoField | Value | |
Title |
CHALLENGES AND POSSIBLE SOLUTIONS IN DETERMINING INR
ВОЗМОЖНЫЕ ИСТОЧНИКИ ОШИБОК ПРИ ОПРЕДЕЛЕНИИ МНО И ПУТИ ИХ РЕШЕНИЯ |
|
Creator |
E. Titaeva V.; Russian Cardiology Research and Production Complex FGBU of the Ministry of Health of the Russian Federation, Moscow
A. Dobrovolsky B.; Russian Cardiology Research and Production Complex FGBU of the Ministry of Health of the Russian Federation, Moscow Е. ТИТАЕВА В.; ФГБУ Российский кардиологический научно-производственный комплекс МЗ РФ, Москва А. ДОБРОВОЛЬСКИЙ Б.; ФГБУ Российский кардиологический научно-производственный комплекс МЗ РФ, Москва |
|
Subject |
—
антагонисты витамина К;протромбиновый комплекс;тромбопластин;степень коагуляции;коагулометр |
|
Description |
Despite the development of new oral anticoagulants, vitamin K antagonists (VKA) continue to be widely used for the treatment and prevention of throm-boembolic complications. On top of that, they have no alternative in patients with artificial heart valves. Receiving AVC results in the synthesis of modified factors of pro-thrombin-converting complex (prothrombin, factor X, IX and VII, as well as two components of the anticoagulant system — protein C and protein S) without capacity to bind with the phospholipid surface, which significantly reduces the likelihood of intravascular thrombosis, but the degree of anti-coagulation is individual and requires monitoring for each patient. Prothrombin test (PT test) is used to monitor the degree of anti-coagulation, which is based on determining the plasma clotting time in a patient after addition of thromboplastin and calcium chloride (prothrombin time). Tromboplastin is animal tissue extract containing tissue factor and phospholipids. In practice, the determination of the anti-coagulation degree by prothrombin time is no easy task. The fact of the matter is that various thromboplastin drugs have different sensitivity to the reduction of factors of prothrombin-converting complex; clotting time of normal and pathologic plasma depends on used thromboplastin and differs even for different series of thromboplastin supplied by the same manufacturer. In addition, prothrombin time depends on the method used (coagulometer). WHO had adopted a system of reporting the PT test results in the form of INR (International normalized ratio) specifically to measure the degree of anti-coagulation in patients who receive oral anticoagulant therapy.
Несмотря на появление новых оральных антикоагулянтов, антагонисты витамина К (АВК) продолжают широко использоваться для лечения и профилактики тром-боэмболических осложнений, а у больных с искусственными клапанами сердца им пока нет альтернативы. При приеме АВК у больных синтезируются измененные факторы протромбинового комплекса (протромбин, фактор X, IX и VII, а также два компонента противосвертывающей системы — протеин С и протеин S), утратившие способность связываться с поверхностью фосфолипидов. В результате существенно снижается вероятность внутрисосудистого тромбообразования, но степень антикоагуляции индивидуальна и требует контроля для каждого пациента. Для контроля используется протромбиновый тест (ПТ-тест), в основе которого лежит определение времени свертывания плазмы пациента после добавления к ней тромбопластина и хлорида кальция (протромбинового времени). Тромбопла-стин — это экстракт тканей животных, содержащий тканевой фактор и фосфоли-пиды. Как показала практика, определение степени антикоагуляции по протром-биновому времени — непростая задача. Дело в том, что разные препараты тромбопластина обладают разной чувствительностью к снижению содержания факторов протромбинового комплекса, время свертывания нормальной и патологической плазмы зависит от используемого препарата тромбопластина и отличается даже для разных серий тромбопластина одного и того же производителя. Кроме того, протромбиновое время зависит от используемого метода (коагулометра). Специально для оценки степени антикоагуляции у больных, находящихся на терапии оральными антикоагулянтами, ВОЗ была принята система представления результатов ПТ-теста в виде МНО (международного нормализованного отношения). |
|
Publisher |
«REMEDIUM GROUP» Ltd.
|
|
Contributor |
—
— |
|
Date |
2016-05-31
|
|
Type |
info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion — — |
|
Format |
application/pdf
|
|
Identifier |
http://www.aterotromboz.ru/jour/article/view/53
10.21518/2307-1109-2015-2-107-114 |
|
Source |
Atherothrombosis Journal; № 2 (2015); 107-114
Атеротромбоз; № 2 (2015); 107-114 2307-1109 10.21518/2307-1109-2015-2 |
|
Language |
rus
|
|
Relation |
http://www.aterotromboz.ru/jour/article/view/53/79
Guidelines for thromboplastin and plasma used to control oral anticoagulant therapy. WHO Technical Report Series, 889, 1999. Панченко Е.П., Добровольский А.Б. Тромбозы в кардиологии. Механизмы развития и возможности терапии. М., 1999, с. 217-243. Houbouyan LL, Goguel AF. Long-term French experience in INR standardization by a pro-cedure using plasma calibrants. Am JClinPathol, 1997. 108:83-9. Poller L, Barrowcliffe TW, Van Den Besselaar AMHP, Jespersen J, Tripodi A, Houghton D. The European Concerted Action on Anticoagulation (ECAA) Evaluation of a Set of Lyophilized Normal Plasmas to Establish the Normal Prothrombin Time for Coagulometer Systems. Thromb Haemost, 1998: 122-128. Van Den Besselaar AMHP, Barrowcliffe TW, Houbouyan-Reveillard LL, Jespersen J, Johnston M, Poller L, Tripodi A. On behalf of the subcommittee on control of anticoagulation of the scientific and standardization committee of the ISTH. Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination. / Thromb Haemost, 2004. 2: 1946-53. Poller L, Ibrahim S, Keown M, Pattison A, Jespersen J. The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers — two independent studies.J Thromb Haemost, 2011. 9: 140-8. Tripodi A, Chantarangkul V, Legnani C, Frontoni R, Testa S. Discrepancy of the international normalized ratio observed in the external quality assessment survey: a cause for concern.J Thromb Haemost, 2012. 10: 714-6. Mearns ES, Kohn CG, Song J-S et al. Meta-Analysis to Assess the Quality of International Normalized Ratio Control and Associated Outcomes in Venous Thromboembolism Patients. Thrombosis Research, 2014. 134: 310-319. Iijima S, Baba T, Ueno D, Ohishi A. International normalized ratio testing with point-of- care coagulometer in healthy term neonates. BMC Pediatr, 2014. 14: 179. doi: 10.1186/1471-2431-14-179. Ebner M, Peter A, Spencer C, Hartig F, Birschmann I, Kuhn J, Wolf M, Winter N, Russo F, Zuern CS, Blumenstock G, Ziemann U, Poli S. Point-of-Care testing of coagulation in patients treated with non-vitamin K oral anticoagulants. Stroke, 2015.46(10): 2741-7. doi: 10.1161/STROKEAHA.1 15.010148. Ruff CT, Giugliano RP, Braunwald E. Comparison of the efficacy and safety of new oral anticoagulants with warfarin in patients with atrial fibrillation: a meta-analysis of randomised trials. Lancet, 2013. published online Dec 4. http://dx.doi.org/10.1016/ S0 140-6736(13)62343-0. DeSantis G, Hogan-Schlientz J, Liska G et all. STABLE Results: Warfarin Home Monitoring Achieves Excellent INR Control. AmJManag Care, 2014. 20 (3): 202-209. Brouwer JLP, Stoevelaar H, Sucker C. The Clinical Impact of Different Coagulometers on Patients Outcomes. Adv Ther, 2014. 31: 639-656. Heneghan C, Ward A, Perera R et all. Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data. Lancet, 2012. 379: 322-34. Plesch W, Wolf T, Breitenbeck N et al. Results of the performance verification of the CoaguChek XS System. Thromb Res, 2008. 123: 381-389. Deom A, Reber G, Tsakiris DA et al. Evaluation of the CoaguChek XS Plus system in a Swiss community setting. Thromb Haemost, 2009. 101: 988-990. Van den Besselaar AMHP, Pequeriaux NCV, Ebben M, et al. Point-of-care monitoring of vitamin K-antagonists: validation of CoaguChek XS test strips with international standard thromboplastin.JClinPathol, 2012. 65: 1031-1035. |
|
Rights |
Authors who publish with this journal agree to the following terms:Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
Авторы, публикующие в данном журнале, соглашаются со следующим:Авторы сохраняют за собой авторские права на работу и предоставляют журналу право первой публикации работы на условиях лицензии Creative Commons Attribution License, которая позволяет другим распространять данную работу с обязательным сохранением ссылок на авторов оригинальной работы и оригинальную публикацию в этом журнале.Авторы сохраняют право заключать отдельные контрактные договорённости, касающиеся не-эксклюзивного распространения версии работы в опубликованном здесь виде (например, размещение ее в институтском хранилище, публикацию в книге), со ссылкой на ее оригинальную публикацию в этом журнале.Авторы имеют право размещать их работу в сети Интернет (например в институтском хранилище или персональном сайте) до и во время процесса рассмотрения ее данным журналом, так как это может привести к продуктивному обсуждению и большему количеству ссылок на данную работу (См. The Effect of Open Access). |
|